Description of CME Course

Importance  Just-in-time interventions (JITIs) are a type of digital therapeutic intervention that combines remote monitoring tools and algorithms to personalize the delivery of specific interventions at the right time. The US Food and Drug Administration (FDA) regulatory approval documents are often the only available source of information on the effectiveness of therapeutic interventions based on these devices.

Objective  To systematically review the publicly available information from the FDA on all recently approved medical devices used in JITIs to (1) assess how they operate to deliver JITIs and (2) appraise the evidence supporting their performance and clinical effectiveness.

Evidence Review  Two reviewers systematically searched the Premarket Notifications (510(k)), Premarket Approvals, De Novo, and Humanitarian Device Exemption databases from January 2019 to December 2021 for all entries associated with devices that monitored patients’ data over time to personalize the delivery of interventions to treat, prevent, or mitigate health conditions or events. They assessed whether the product summaries (1) enabled an understanding of how the device operated to deliver a JITI (eg, the nature, type, and frequency of the monitoring, the nature of the decision algorithm, and the nature and intended receiver of the intervention); (2) informed about the performance and effectiveness of the JITI; and (3) included information on data security and ownership.

Findings  In total, 38 devices were included in this review. These were mainly intended for cardiac conditions (12 [31.6%]), diabetes (10 [26.3%]), and neurological diseases (4 [10.5%]). Monitoring devices ranged from wearable (18 of 28 [64.4%]; eg, smartwatches) to implanted sensors (6 of 28 [21.4%]; eg, inserted electrocardiographic sensors). Only 10 of 38 product summaries (26.3%) allowed a full understanding of how the device operated to deliver a JITI. Similarly, only 12 of 28 (42.9%), 12 of 36 (33.3%), and 5 of 38 (13.2%) reported the assessment of the performance of the monitoring device, assessment of the decision algorithm, and results of clinical studies assessing the effectiveness of the JITI, respectively. Finally, 14 of 36 product summaries (38.9%) included some information on data security, but none included information on data ownership.

Conclusion and Relevance  The results of this systematic review suggest that the information publicly available in the FDA databases on the performance and effectiveness of digital medical devices used in JITIs is heterogeneous.

Disclaimers

1. This activity is accredited by the American Medical Association.
2. This activity is free to AMA members.

Register for this Activity

ABMS Member Board Approvals by Type
More Information
Commercial Support?
No

NOTE: If a Member Board has not deemed this activity for MOC approval as an accredited CME activity, this activity may count toward an ABMS Member Board’s general CME requirement. Please refer directly to your Member Board’s MOC Part II Lifelong Learning and Self-Assessment Program Requirements.

Educational Objectives

To identify the key insights or developments described in this article

Keywords

Cardiology, Diabetes, Health Policy, Medical Devices and Equipment, Regulatory Agencies